Weymouth vs. Panhandle A & B: Choosing the Right Gas Pipeline Flow Equation

Compare applicable pipe diameters, turbulence regimes, efficiency factors, and diameter exponents across Weymouth, Panhandle A, and Panhandle B gas flow equations.

GPSA Engineering Data BookASME / AGA Gas HydraulicsGB 50251
Run this calculation live

Gas Flow (Weymouth/Panhandle)

Open Calculator →

Why Different Gas Flow Equations Diverge by 10%–25%

Weymouth, Panhandle A, and Panhandle B are the three classic explicit isothermal gas flow equations derived from the general flow equation. They differ primarily in how each empirical correlation approximates the Darcy friction factor f.

Using Weymouth on a large high-pressure trunkline typically underpredicts capacity conservatively, whereas applying Panhandle B to small, rougher gathering lines can overpredict throughput and leave insufficient pressure margin.

Comparison of Weymouth, Panhandle A, and Panhandle B Equations

EquationTypical Pipe SizeTurbulence RegimeTypical Efficiency EDiameter Exponent
Weymouth Small to medium bore (≤ 12 in / DN300) gathering & distribution High relative roughness, conservative fully turbulent 0.85 – 0.95 2.667
Panhandle A Medium-large bore (12–24 in / DN300–DN600) transmission Partially turbulent (Re ≈ 5×10⁶–1.1×10⁷) 0.88 – 0.92 2.6182
Panhandle B Large-bore high-pressure trunklines (≥ 20 in / DN500) Fully turbulent high-Reynolds flow (Re ≈ 4×10⁶–4×10⁷) 0.88 – 0.95 2.53

Core Equations & Meaning of the Pressure-Squared Term

All three equations share the same physical backbone: standard throughput scales roughly with efficiency E and the square root of (P₁² − P₂²), inversely with √(G·T_f·L·Z), and very strongly with internal diameter D (exponents from 2.53 to 2.667).

Because the diameter exponent exceeds 2.5, a 10% increase in inside diameter boosts flow capacity by roughly 27%–29% at the same pressure drop. Always enter the actual inside bore D rather than nominal outside diameter.

Standard Weymouth & Panhandle B Forms (Metric Engineering Units)
QWey=3.7435×10−3 E TbPb(P12−P22GTfLZ)0.5D2.667,QPanB=1.002×10−2 E(TbPb)1.02(P12−P22G0.961TfLZ)0.51D2.53Q_{\text{Wey}} = 3.7435 \times 10^{-3} \, E \, \frac{T_b}{P_b}\left(\frac{P_1^2 - P_2^2}{G T_f L Z}\right)^{0.5} D^{2.667}, \qquad Q_{\text{PanB}} = 1.002 \times 10^{-2} \, E \left(\frac{T_b}{P_b}\right)^{1.02}\left(\frac{P_1^2 - P_2^2}{G^{0.961} T_f L Z}\right)^{0.51} D^{2.53}

Valid for horizontal isothermal steady flow. Mountainous routes with significant elevation change require an elevation correction term or segmented Colebrook-White simulation.

Four Common Pitfalls in Pipeline Hydraulic Calculations

Even with the right equation selected, calculation discrepancies over 5% almost always come from one of these four input mistakes:

  • Using gauge instead of absolute pressure: P₁ and P₂ must be absolute. On low-pressure lines (e.g., 0.4 MPa gauge), omitting local atmospheric pressure creates >15% error.
  • Assuming Z = 1.0 at high pressure: At 6–10 MPa ambient conditions, natural gas Z is typically 0.80–0.88; assuming ideal gas underpredicts throughput by 6%–10%.
  • Skipping velocity checks: Acceptable pressure drop does not guarantee safe velocity; always screen flowing velocity against economic and API RP 14E erosional limits.
  • Mismatched base conditions (T_b / P_b): Comparing volumes at 20 °C (China) vs. 15 °C (ISO) vs. 0 °C (DIN) introduces up to 7.3% discrepancy for the exact same mass flow.
Quick Selection Rule

Use Weymouth for conservative small gathering lines, Panhandle A for medium-large partially turbulent lines, and Panhandle B for large high-pressure trunklines—then refine with Colebrook-White in detailed design.

Worked Example: 482.6 mm High-Pressure Gas Trunkline Comparison

A 50 km horizontal pipeline with inside diameter D = 482.6 mm (20 in bore), inlet P₁ = 6.0 MPa(a), outlet P₂ = 4.0 MPa(a), flowing temperature T_f = 20 °C, specific gravity G = 0.60, compressibility Z = 0.88, efficiency E = 0.92 at 20 °C / 101.325 kPa reference.

  1. 1. Average pressure: P_avg = (2/3) × (6.0 + 4.0 − 24/10) = 5.067 MPa(a), confirming the assumed Z = 0.88 is consistent with average line pressure.
  2. 2. Weymouth yields a conservative lower bound; switching to Panhandle B predicts ~4.75 × 10⁶ m³/d (~168 MMSCFD), closely matching modern large-bore trunkline performance.
  3. 3. Verify flowing velocity at the lower-pressure outlet (4.0 MPa) remains safely below 15 m/s economic guidance and API RP 14E erosional velocity.

Open the calculator below to toggle between Weymouth, Panhandle A, and Panhandle B with these exact inputs and compare throughput or outlet pressure instantly.

Open Gas Flow (Weymouth/Panhandle) →

Frequently Asked Questions

What efficiency factor E should I use, and can it exceed 1.0?

New internally coated lines typically use 0.92–0.95, normal operating lines 0.85–0.92, and fouled or wet lines 0.70–0.80. Physically E cannot exceed 1.0.

How do I solve for outlet pressure P₂ when flow rate and inlet pressure are known?

Rearranging the equation for (P₁² − P₂²) yields P₂ directly. If the required Δ(P²) exceeds P₁², the target flow is hydraulically infeasible without a larger bore, higher inlet pressure, or compression.