Gas Pipeline Flow & Pressure Drop Calculator
Calculate standard gas throughput, downstream pressure, pressure drop, average pressure, and mean velocity using Weymouth, Panhandle A, and Panhandle B equations.
Hydraulic results
Default exampleEquations & Engineering Basis
Nomenclature & Units
| Symbol | Parameter | Units | Engineering Notes |
|---|---|---|---|
| Inlet & outlet absolute pressure | kPa (方程内部) / MPa / psi | Gauge inputs are converted to absolute using local atmospheric pressure. | |
| Pipe inside diameter | mm (方程内部) / in | Use actual bore (OD minus 2× wall thickness). | |
| Pipe length | km (方程内部) / mi | Level pipeline assumption without elevation correction. | |
| Specific gravity, Z-factor & temp | -, -, K | Evaluated at average pipeline pressure and temperature. | |
| Pipeline efficiency | 0 < E ≤ 1 | Accounts for wall roughness, liquids, and minor losses. |
Engineering Scope & Benchmark
Benchmark: P₁=6 MPa(a), P₂=5 MPa(a), D=500 mm, L=100 km, G=0.65, E=0.90, T_f=300 K, Z=0.90 at 20 °C / 101.325 kPa gives ~385.13 (Weymouth), ~473.00 (Panhandle A), and ~475.24 ×10⁴ m³/d (Panhandle B).
Level, steady-state, isothermal single-phase gas flow with unit reference compressibility (Z_ref = 1.0).
Frequently Asked Questions
How do I choose between Weymouth, Panhandle A, and Panhandle B?
Weymouth is conservative and suited for smaller-bore gathering/distribution lines. Panhandle A covers medium-to-large partially turbulent lines, while Panhandle B targets large-diameter, high-pressure, fully turbulent trunklines.
Why does solving for P₂ sometimes return a physical domain error?
When the requested flow rate is too high for the given inlet pressure and bore, the calculated P₂² drops to ≤ 0, meaning the line cannot physically pass that flow without higher inlet pressure or larger diameter.
Why is reference compressibility Z_ref fixed at 1.0 for this tool?
Classical Weymouth and Panhandle empirical constants assume Z_b ≈ 1 at standard conditions and carry no separate Z_b factor; locking Z_ref = 1 preserves consistency with published standards.