Gas Actual/Reference, Mass & Energy Flow Converter
Bidirectionally convert actual and reference gas volumetric flow under explicit reference T, P, and Z, alongside compressibility ratio F_z, mass flow, and energy flow.
Metering conversion results
Default exampleEquations & Engineering Basis
Nomenclature & Units
| Symbol | Parameter | Units | Engineering Notes |
|---|---|---|---|
| Flowing absolute P, T & Z | Pa / MPa, K / °C, - | Actual gas state at the flowmeter measurement point. | |
| Reference P, T & Z | 101.325 kPa, 20 °C / 0 °C / 60 °F, 1.0 | China/ISO standard is 20 °C / 101.325 kPa; DIN normal is 0 °C; US API is 60 °F. | |
| Reference density & HHV | kg/m³, MJ/m³ / Btu/ft³ | Must correspond to the exact same reference state as Q_ref. |
Engineering Scope & Benchmark
Benchmark: For an ideal gas (Z_f = Z_ref = 1) at equal pressure 101.325 kPa, converting from 0 °C actual to 20 °C reference yields the exact ratio 293.15 / 273.15 ≈ 1.073220.
Density and volumetric heating value correspond to the selected reference state; dry gas basis.
Frequently Asked Questions
How much difference is there between 20 °C (Sm³) and 0 °C (Nm³) reference volumes?
At 101.325 kPa, the 20 °C vs 0 °C temperature ratio alone creates a 7.322% volume difference. Always verify the reference temperature in the expandable Reference Conditions panel.
What is the supercompressibility factor F_z used for?
F_z = √(Z_ref / Z_f) is the square-root compressibility factor commonly used in differential-pressure meters (such as orifice plates).
Should heating value and density be updated when changing reference temperature?
Yes. Volumetric heating value and reference density are defined per unit reference volume, so both scale when moving between 20 °C, 0 °C, and 60 °F bases.