Gas Pipe Sizing, Actual Velocity & Erosional Limit
Compute actual gas velocity or minimum required inside diameter, flowing gas density, actual flow rate, and API RP 14E erosional velocity screening.
Sizing & screening results
Default exampleEquations & Engineering Basis
Nomenclature & Units
| Symbol | Parameter | Units | Engineering Notes |
|---|---|---|---|
| Reference & actual flow | ref-m³/h, m³/s | Reference state defaults to 20 °C, 101.325 kPa, Z=1 (editable). | |
| Gas constant & air molar mass | 8314.46 J/(kmol·K), 28.964 kg/kmol | Fixed SI physical constants used internally. | |
| Empirical erosion factor | Ce(SI) / Ce(US) | 122 (SI) = 100 (US). Triggers danger above v_e and warning above 15 m/s. |
Engineering Scope & Benchmark
Process station gas piping is typically kept below 15–20 m/s for noise and pressure-loss control, and must not exceed the API RP 14E erosional limit v_e. Reduce C_e substantially if solids or corrosive liquids are present.
Single-phase steady continuity flow; erosional limit is an empirical screening check based on API RP 14E C_e.
Frequently Asked Questions
What is the difference between the erosional limit and the 15 m/s screening alert?
Exceeding v_e is a high-severity mechanical integrity alert (risk of protective film stripping and erosion), whereas > 15 m/s is an economic/noise screening warning that may be acceptable in short runs or high-pressure clean service.
Why is actual gas velocity much lower in high-pressure pipelines?
At fixed standard flow, actual volume Q_a scales inversely with absolute pressure P. Downstream of a pressure-reducing regulator, pipe bore must increase significantly to keep velocity safe.
How do SI (122) and US customary (100) values of C_e relate?
The conversion factor is 1.22 (100 in US units ≈ 122 in SI units). You can switch directly between Ce(SI) and Ce(US) in the unit selector.