Pipeline PIR (HCA) & Choked Sonic Leak Rate Estimator
Calculate sweet natural gas Potential Impact Radius (PIR) and affected area per GB 32167 / ASME B31.8S, plus adiabatic choked sonic gas mass leak rate.
Integrity & safety results
Default exampleEquations & Engineering Basis
Nomenclature & Units
| Symbol | Parameter | Units | Engineering Notes |
|---|---|---|---|
| OD (mm) & MAOP (MPa abs) | mm, MPa(a) | Dimensional units strictly normalized; eliminates 1000× unit ambiguity. | |
| Orifice area & discharge coeff | mm² / m², 0 < C_d ≤ 1 | Default C_d = 0.62 for sharp-edged puncture. | |
| Heat capacity ratio & molar mass | k > 1, kg/kmol | Typical natural gas: k = 1.30, M ≈ 16.0–17.5 kg/kmol. |
Engineering Scope & Benchmark
Benchmark: D = 508 mm (20 in) at MAOP = 6.3 MPa(a) yields r = 0.099 × 508 × √6.3 ≈ 126.23 m (matching ASME B31.8S imperial 0.69·d·√p ≈ 417.1 ft ≈ 127.1 m within < 1%).
PIR applies to sweet natural gas thermal radiation (not sour H₂S toxicity); sonic leak rate assumes ideal adiabatic choked initial release.
Frequently Asked Questions
What gas composition and radiation threshold does the 0.099 PIR factor assume?
The 0.099 factor (D in mm, P in MPa abs, r in m) corresponds to sweet natural gas at the 15.8 kW/m² (5000 Btu/h·ft²) thermal flux threshold in GB 32167 and ASME B31.8S. Sour gas or liquid hydrocarbons require separate models.
Why does choked leak mode reject P_b/P above the critical pressure ratio?
For k = 1.30, the critical ratio is ~0.546 (internal absolute pressure must exceed ~1.83× ambient pressure). Below that threshold the flow is subsonic and the choked equation is invalid.
Can initial choked leak rate estimate total release over time for a full-bore rupture?
No. The equation gives the initial peak release rate before line depressurization. Total release over time requires transient blowdown modeling.