Pipeline PIR (HCA) & Choked Sonic Leak Rate Estimator

Calculate sweet natural gas Potential Impact Radius (PIR) and affected area per GB 32167 / ASME B31.8S, plus adiabatic choked sonic gas mass leak rate.

Inputs

SI
Absolute pressure is required per V3 specification.

Integrity & safety results

Default example
126.232
50059.7

Uses the V3 sweet-gas model and its absolute-pressure convention.

Formula version 3.0.0 · Reference conditions: not applicable2026-11-26T11:14:16.248Z · For preliminary estimates and education only. Qualified engineering review required.

Equations & Engineering Basis

GB 32167ASME B31.8SAPI RP 581
Sweet Natural Gas PIR (15.8 kW/m² Thermal Threshold)
r=0.099⋅Dmm⋅PMPa(m),APIR=πr2r = 0.099 \cdot D_{\text{mm}} \cdot \sqrt{P_{\text{MPa}}} \quad (\text{m}), \qquad A_{\text{PIR}} = \pi r^2
Adiabatic Choked Sonic Mass Leak Rate
Wg=Cd⋅SK⋅PM⋅kRu⋅T(2k+1)k+1k−1,PbP≤(2k+1)kk−1W_g = C_d \cdot S_K \cdot P \sqrt{\frac{M \cdot k}{R_u \cdot T}\left(\frac{2}{k + 1}\right)^{\frac{k + 1}{k - 1}}}, \qquad \frac{P_b}{P} \le \left(\frac{2}{k+1}\right)^{\frac{k}{k-1}}

Nomenclature & Units

Symbol Parameter Units Engineering Notes
Dmm,PMPaD_{\text{mm}}, P_{\text{MPa}} OD (mm) & MAOP (MPa abs) mm, MPa(a) Dimensional units strictly normalized; eliminates 1000× unit ambiguity.
SK,CdS_K, C_d Orifice area & discharge coeff mm² / m², 0 < C_d ≤ 1 Default C_d = 0.62 for sharp-edged puncture.
k,Mk, M Heat capacity ratio & molar mass k > 1, kg/kmol Typical natural gas: k = 1.30, M ≈ 16.0–17.5 kg/kmol.

Engineering Scope & Benchmark

Benchmark: D = 508 mm (20 in) at MAOP = 6.3 MPa(a) yields r = 0.099 × 508 × √6.3 ≈ 126.23 m (matching ASME B31.8S imperial 0.69·d·√p ≈ 417.1 ft ≈ 127.1 m within < 1%).

PIR applies to sweet natural gas thermal radiation (not sour H₂S toxicity); sonic leak rate assumes ideal adiabatic choked initial release.

Frequently Asked Questions

What gas composition and radiation threshold does the 0.099 PIR factor assume?

The 0.099 factor (D in mm, P in MPa abs, r in m) corresponds to sweet natural gas at the 15.8 kW/m² (5000 Btu/h·ft²) thermal flux threshold in GB 32167 and ASME B31.8S. Sour gas or liquid hydrocarbons require separate models.

Why does choked leak mode reject P_b/P above the critical pressure ratio?

For k = 1.30, the critical ratio is ~0.546 (internal absolute pressure must exceed ~1.83× ambient pressure). Below that threshold the flow is subsonic and the choked equation is invalid.

Can initial choked leak rate estimate total release over time for a full-bore rupture?

No. The equation gives the initial peak release rate before line depressurization. Total release over time requires transient blowdown modeling.